VOC test chambers

VOC Emission Test Chambers

Copertina 636x534

 

Chambers for volatile organic compounds (VOC) and formaldehyde emission tests according to international standards as ISO 16000-9, UNI CEN/TS 16516, GEV testing methods, ASTM D5116, ASTM D6007, UNI EN 717-1, GREENGUARD UL2818, UL2819, UL2820, UL2821, UL2822, UL2823 and many other technical standards.

These systems are fully automatic: once either the required reference standard (e.g. ISO 16000-9, CEN/TS 16516 etc.) is selected for the test chamber the system loads the paramenters and times of the selected standard and:
. controls environmental conditions (Temperature, Relative Humidity, Air changes per hour and air velocity) inside the test chamber
. alerts the operator via mail, with the set advance, when the air sampling ir required
. ends the test and generates the test report, sending it by e-mail to the preset addresses.
. sends alarms, alerts and memoranda to the operator via mail

If desired the test parameters can be manually set.

Visit the Page for selection of the Reference Technical Standard and for the setting of optional advanced functionalities

A remarkable feature of the 250L/225L test chambers is that they are suitable both for VOC and formaldehyde emission tests according to the reference standards listed above and for formaldehyde tests according to UNI 717-1.

Standard available configurations:

. 8 test chambers, 110 L each, full-optional version

. 6 test chambers, 250 L each, full optional version
. 4 test chambers, 250 L each, full optional version
. 2 test chambers, 250 L each, full optional version

. 1 test chamber, 1000 L, full-optional version

. 1 test chamber, 6000 L, full-optional version

. 8 test chambers, 110 L each, basic configuration stand-alone unit, fully and independently operating VOC emission tests, w/o measures and controls inside the test chambers, ready to be implemented to the full-optional version (our standard design)

Note: all the 250 L test chambers can be supplied c/w a volume compensator to reduce volume to 225 L and c/w a second air velocity meter. In this way the 250L/225L can be used both for formaldehyde emission test acc. to UNI 717-1 and to VOC/formaldehyde emission test according to all the other standards.

These are our standard systems and the more frequently required by Customers; we can design and manufacture other configurations on request.

Visit the page General System description in the standard configurations for details

Visit the Photo Gallery

Maintenance 

VOC emission test chamber Systems maintenance requirements and consumable replacement frequency depend upon use conditions. Filters life expectancy is fixed by the supplier to 2 years. 
CLR Srl offers two different service agreements that can be subscribed by the Customer with costs that remain fixed for 2 years including the cost of consumable parts as listed.
During scheduled maintence visits CLR engineer will operate preventive maintenance and diagnostics of all system components; every 24 months he will replace the filters at the inlet of the system.
In case no service agreement is undersigned, CLR Engineers are always available for technical assistance on site upon Customer request. The cost of this technical assistence is listed in our document “CLR - Service Conditions” and the replaced parts will be separately invoiced together with the service
The most important advantage of a scheduled maintenance agreement is to avoid any unexpected dowtime that, if occurring during a long term test, would lead to a loss of days of work.

References
You can ask us the reference list for VOC emission test chambers: pls contact us at the mail or phone number You find in the CONTACTS page.