Differential pH-ORP Electrodes

125 diff pH

Differential pH electrodes,  Mod.125

Differential pH electrodes designed for pH measurements in very difficult applications where standard pH electrodes cannot work because the reference electrode life would be too short as, for example,  those processes including fouling  or fatty substances that  would deposit on the reference electrode making the measurement impossible and processes containing substances that react with traditional reference electrodes destroying them, such as Hg++, Pb++, Cu++, ClO4-, Ag+, Br-, I-, CN-, S= ions.
These sensors are fully interchangeable with any other pH electrode and are suitable to be used with any pH meter and even with voltmeters and PLC.
An economically interesting solution is the use of these sensors in conjunction with our standard pH meter Mod.uP01, uPLT01, uP01R, TX01, TX-HMI 01.
The reference electrodes used in differential pH electrodes are not subject to the negative effect that stray currents have on inner metal electrodes of traditional reference electrodes.      In all these applications, where traditional pH electrodes would have a short life, the differential pH electrodes assure long term reliability with almost no maintenance requirements.
Mod.125 is a differential pH electrode, PP (Mod.125A1xx)  or PVDF (Mod.125A2xx) body, 40 mm diameter, 245 mm length,  suitable for immersion installation; it includes the threaded connection for the installation into Mod.SI0V immersion probe, available in various materials and different  lengths.
The measuring electrode has hemispheric glass membrane, the reference electrode is included inside the body and is immersed into the salt bridge,  separated from it by a glass membrane.   The large area porous diaphragm is made of PVDF.        The sensor includes the solution ground contact and the temperature sensor, Pt100, for temperature indication and for measure thermo compensation.         An electronic circuit included in the sensor and self powered by an integral battery (interchangeable) transforms the  signal from the electrodes into a standard, low impedance signal  ±500 mV (Mod.125AxAx)  or 0-1 V (Mod.125AxBx).
The electrode is supplied c/w  integral cable, the cable shield is connected to the metal sheath of the Pt100 temperature sensor so that connecting it to the ground of the instrument the solution in measure results grounded also (this is essential for the good operation of each analyser).
Operating temperature limits: 0-80 °C (PP) 0-100°C (PVDF)
Operating pressure limits:   5 bar @ ambient temperature
Cable:   integral,  5 m (Mod.125Axx1), 10 m (Mod.125Axx2), 15 m (Mod.125Axx3)
Differential pH electrodes  are designed for pH measurements in very difficult applications, such  as thepH measure in tanning process; pH control in harsh processes; pH measure in highly poisoning water, e.g. pH analysis in samples containing sulphides S=, silver ions Ag+, bromides Br-, iodides I-, Cyanides CN-, pH analysis in spring water containing sulphides.
The sensor has been succesfully used for pH analysis in tannery, pH measure in spa water with high temperature and high concentration of sulphides S=, pH analysis in spring water pools.

225 Differential ORP Electrode

125 diff pH

Differential ORP electrodes Mod.225

Differential ORP electrodes designed for ORP measurements in very difficult applications where standard ORP electrodes cannot work because the reference electrode life would be too short as, for example,  those processes including fouling  or fatty substances that  would deposit on the reference electrode making the measurement impossible and processes containing substances that react with traditional reference electrodes destroying them, such as Hg++, Pb++, Cu++, ClO4-, Ag+, Br-, I-, CN-, S= ions. 
These sensors are fully interchangeable with any other ORP electrode and are suitable to be used with any ORP meter and even with voltmeters and PLC. 
An economically interesting solution is the use of these sensors in conjunction with our standard ORP meter Mod.uP03, uPLT03, uP03R, TX03, TX-HMI03.
The reference electrodes used in differential ORP electrodes are not subject to the negative effect that stray currents have on inner metal electrodes of traditional reference electrodes.      In all these applications, where traditional ORP electrodes would have a short life, the differential ORP electrodes assure long term reliability with almost no maintenance requirements. 
Mod.225 is a differential ORP electrode, PP (Mod.225x1xx)  or PVDF (Mod.225x2xx) body,  40 mm diameter, 245 mm length, suitable for immersion installation; it includes the threaded connection for the installation into Mod.SI0V immersion probe, available in various materials and different  lengths.
The measuring electrode can be made of Gold (Mod.225Axxx), Silver (Mod.225Bxxx) Platinum (Mod.225Cxxx) or annular Platinum (225Dxxx),  the reference electrode is included inside the body and is immersed into the salt bridge,  separated from it by a glass membrane.   The large area porous diaphragm is made of PVDF.        The sensor includes the solution ground contact and the temperature sensor, Pt100, for temperature indication.         An electronic circuit included in the sensor and self powered by an integral battery (interchangeable) transforms the  signal from the electrodes into a standard, low impedance signal  ±2000 mV (Mod.225xxAx)  or 0-1 V (Mod.225xxBx).  
The electrode is supplied c/w  integral cable, the cable shield is connected to the metal sheath of the Pt100 temperature sensor so that connecting it to the ground of the instrument the solution in measure results grounded also (this is essential for the good operation of each analyser). 
Operating temperature limits: 0-80 °C (PP) 0-100°C (PVDF)
Operating pressure limits:   5 bar @ ambient temperature
Cable:   integral,  5 m (Mod.225xxx1), 10 m (Mod.225xxx2), 15 m (Mod.225xxx3)
Differential ORP electrodes  are designed for ORP measurements in very difficult applications, such  as the ORP measure in tanning process; Redox control in harsh processes; ORP measure in highly poisoning water, e.g. Redox analysis in samples containing sulphides S=, silver ions Ag+, bromides Br-, iodides I-, Cyanides CN-, ORP analysis in spring water containing sulphides.
The sensor has been succesfully used for ORP analysis in tannery, ORP measure in spa water with high temperature and high concentration of sulphides S=, Redox analysis in spring water pools.


 

uPxxR-gb

uP-IP

PID controller for pH and ORP differential sensors, Mod.uPxxR
Microprocessor based PID controller, fully programmable, suitable for panel mounting (IP54 protection degree) and outdoor installation (IP65 housing). Instrument configuration is easily performed via display and keyboard and calibration is automatic.
Measure and temperature are indicated on a 5 digit red LED display.
Mod.uP can be directly connected to the differential sensor of pH or ORP and to the pertinent temperature sensing element. The measure is compensated for temperature variations, according to dedicated algorithms specific for each parameter and displayed in engineering units. Temperature compensated value is used in the PID algorithm. The PID controller is available either with analogic control output (4-20 mA or 0-10V, galvanically isolated) or with digital control output (conatct output); in this versione the 4-20 mA (or 0-10 V) output is available for temperature compensated measure retransmission.
The instrument provides 4 digital outputs that can be configured as NC or NO via software and can be programmed as low alarm, high alarm, alarm with hysteresis or windows alarm.
The 4 digital outputs are from relays. If the control output is from relay R1 is used for control action.
Two digital inputs are available, one for digital hold of the measure, and one for the input of an external alarm (e.g. level switch, temperature switch etc.)
The instrument is optionally available with cleaning sequence included: in this version it can drive the chemical cleaning of the sensor through a specific algorithm, with programmable timers, driving the detergent pump through R4 relay.
Measuring ranges are:
pH: -1.00 - +15.00 pH;
ORP: - 2000 - +2000 mV;
In the contact output control version the analog output can be freely associated to any interval inside the measuring range.
Power supply: 24 Vac, 115 Vac, 230 Vac, +/- 10%, 50/60 Hz, max.consumption: 3.3 VA